error code e004-0101, e004-0102, e004-0103

Error Code e000004-0101
The IH power supply is faulty/the IH control mechanism is faulty.
After correcting the fault, besure to reset the error.
(COPIER>FUNCTION>CLEAR>ERR)

Descriptions :
There is a mismatch between the input voltage and the IH power supply ID.

Remedy : 
- Replace the fixing heater power supply with one designed for the country of installation (voltage).
- Check the connector for any fault in connection.
- Replace the fixing heater power supply.
- Replace the DC controller PCB

Error Code e000004-0102
There is an abnormal rise in temperature. After correcting the fault, besure to reset the error.
(COPIER>FUNCTION>CLEAR>ERR)

Descriptions : 
The IH current is faulty. (current leakage)

Remedy :
- Replace the fixing heater power supply with one designed for the country of installation (voltage).
- Check the connector for any fault in connection.
- Replace the fixing heater power supply.
- Replace the DC controller PCB

Error Code e000004-0103
There is an abnormal rise in temperature. After correcting the fault, besure to reset the error.
(COPIER>FUNCTION>CLEAR>ERR)

Descriptions : 
The IH current is faulty. (no current)

Remedy :
- Replace the fixing heater power supply with one designed for the country of installation (voltage).
- Check the connector for any fault in connection.
- Replace the fixing heater power supply.
- Replace the DC controller PCB