Error code e001-0001, e001-0002, e001-0003 and e001-0010

Error Code e000001-0001
There is an abnormal rise in temperature. After correcting the fault, besure to reset the error.
(COPIER>FUNCTION>CLEAR>ERR)

Descriptions :
There is an error or an open circuit in the
main thermistor, shutter thermistor, or sub
thermistor.

Remedy : 
- Check the connector of each thermistor for any fault in connection and wiring.
- Replace the thermistor in question.
- Replace the DC controller PCB.

Error Code e000001-0002
There is an abnormal rise in temperature. After correcting the fault, besure to reset the error.
(COPIER>FUNCTION>CLEAR>ERR)

Descriptions : 
The reading of the main thermistor, shutter
thermistor, or sub thermistor is 230 deg C
or higher for 2 sec

Remedy :
- Replace the thermistor in question.
- Replace the DC controller PCB.


Error Code e000001-0003
There is an abnormal rise in temperature. After correcting the fault, besure to reset the error.
(COPIER>FUNCTION>CLEAR>ERR)

Descriptions : 
The reading is not 150 deg C or higher or 210 deg C or lower within 30 sec.

Remedy : 
- Turn off and then back on the power.

Error Code e000001-0010
There is an abnormal rise in temperature. After correcting the fault, besure to reset the error.
(COPIER>FUNCTION>CLEAR>ERR)

Descriptions : 
The power has been turned off and then back on without resetting the error.

Remedy :
- Reset the error.
(COPIER>FUNCTION>CLEAR>ERR)